Further modified on the basis of BXH-105 · Stronger anti-emulsification performance · Specially optimized for oilfield gathering and transportation conditions
| Project | Technical Indicators | Testing Standards/Methods |
|---|---|---|
| Appearance | Brown-red transparent liquid | Visual inspection |
| Solubility | Easily soluble in gasoline, diesel and heavy aromatics | Visual inspection |
| Density (20℃), g/cm³ | 0.95~1.05 | GB/T 2540 |
| Freezing point, ℃ | ≤-15 | GB/T 510 |
| Closed cup flash point, ℃ | ≥65 | GB/T 261 |
| Effective content, % | ≥95 | Solid content, 100℃ |
OEM custom / tolling / blending capabilities:
✔ Multiple stainless steel and enamel reactors with condensation reflux and dosing systems
✔ Thermal oil / steam heating; synthesis temperature up to 250℃
✔ Custom imidazoline, toll synthesis, and finished-product blending
✔ Formula development for oilfield / refinery conditions with sample verification
The corrosion environment of the oilfield gathering and transportation system is complex, with the combined effects of CO₂, H₂S, SRB sulfate-reducing bacteria, and high-salinity produced water, and the produced liquid has a high moisture content. Ordinary oil-soluble corrosion inhibitors often have a tendency to assist emulsification, which will increase the difficulty of dehydrating crude oil and affect the operation of electric dehydration. OEM Oilfield anti-emulsifying imidazoline Low emulsification tendency It is a core design that effectively inhibits corrosion while not interfering with subsequent dehydration treatment. as High temperature and high pressure oilfield corrosion inhibitor and Acidic environment imidazoline, OEM is suitable for acidic gathering and transportation conditions with high water content, high salinity, and CO₂/H₂S.
CO₂ generates carbonic acid and causes general/pitting corrosion, H₂S causes sulfide stress corrosion, SRB aggravates corrosion under scale, and high water content further amplifies the risk. It is necessary to consider both corrosion inhibition and demulsification compatibility.
If the corrosion inhibitor assists emulsification, it will form a stable emulsion during the gathering, transportation and electric dehydration process, which will increase dehydration energy consumption and chemical costs. OEM has low emulsification tendency, is compatible with wax removal and anti-waxing agents, and does not affect dehydration.
Suitable for high water content oil well gathering pipeline network and water injection system with water content >60%, operating temperature 20-120℃, recommended 20-50 mg/L.
Low emulsification tendency, corrosion inhibition while not affecting crude oil dehydration and electric dehydration operations.
Inhibit acid gas corrosion of water injection pipelines and downhole pipe strings.
For CO₂, H₂S composite corrosion film protection, compatible with fungicides.
Fill in the oil field working conditions information and get exclusive formula suggestions and free samples.